Inline High-voltage and current probe
Inline high-voltage and current probe for fast pulse measurment
Off the shelf specifications (custom systems can be made):
- Adjustable amplitude
- Comes with high-voltage output cable
- Built-in power supply
- High-average power
- Fast rise-time pulse
Peak voltage | 20 | kV |
Peak current | 400 | A |
Voltage attenuation | 1000:1 | |
Current attenuation | 20:1 | |
Dimensions: | 267×165 | mm |
Useable risetime | 5 | ns |
Shunt impedance | 1 | kΩ |
Voltage measurement accuracy | ±2 | % |
Current measurement accuracy | ±1 | % |